    1.空调在净化工程中的选择至关重要,由于在设计与施工中空调的耗能量大,所以我们需关注节能措施。在设计中,区域的以及系统的划分,送风量的计算,温度的相对稳定,干净等级和换风次数确实定,风管的保温,以及法兰的链接能否完好、空调箱、冷水机组、风机等设备的选择都与能耗量息息相关,这些细节都是我们再设计与施工中必需要思索的细节。
    1. The selection of air-conditioning in purification project is very important. Because air-conditioning consumes the most energy in design and construction, we need to pay attention to energy-saving measures. In the design, the division of area and system, the calculation of air supply volume, the relative stability of temperature, the determination of cleanliness grade and frequency of air exchange, the insulation of air duct, and the selection of flange links, air conditioning box, chiller, fan and other equipment are closely related to energy consumption. These details are the necessary considerations in our redesign and construction.
    2.在装修队进场时的件事就是对空中的评价,假如空中足够平整的话,简单弄一下就能够了。否则,就需求找平,这项费用完整不能省,不能怪开发商,只能怪运气。不论空中终是选用地毯还是木地板,平整的空中都是绝对的前提。
    2. When the decoration team enters the field, the first thing is the evaluation of the air. If the air is smooth enough, it can be done simply. Otherwise, the demand will be leveled, the cost can not be saved completely, we can not blame the developers, we can only blame luck. Whether carpet or wooden floor is the ultimate choice in the air, even air is the absolute prerequisite.
    空气净化工程
    3.在净化工程净化空调系统中,风管的性能很重要,一定要紧密性好、不发尘、不积尘、不污染、耐潮、耐腐蚀。在运转中,普通风管的部分阻力高于风管的沿程阻力,这点需留意,遇到这种状况需求改善。
    3. In the air-conditioning system of purification project, the performance of air duct is very important. It must be compact, dust-free, dust-free, pollution-free, moisture-resistant and corrosion-resistant. In operation, the resistance of the common duct is higher than that along the duct, which needs to be noticed. In this case, it needs to be improved.
    4.现代抵消防的请求有相关的标准,假如你要吊顶,室内一切的喷淋口一定要显露吊顶一定尺寸,而且要料理程度。
    4. Modern fire protection requirements have relevant standards. If you want a ceiling, all indoor sprinklers must show a certain size of the ceiling, and the degree of care.
    5.假如室内隔出了新的空间,依照消防标准,必需增加单独的烟感器,而且还是要请专业公司来做,普通是大楼的维保单位。这一项和上面那项假如改不好的话,是通不过验收的。
    5. If a new space is separated from the room, according to the fire protection standard, it is necessary to add a separate smoke sensor, but also to ask professional companies to do it, usually the maintenance unit of the building. If this item and the above item are not corrected properly, they will not pass the acceptance test.
    6.很多净化工程装修过程中,由于范围小,弱电改造(包括网线和电话线)常常不会请特地的综合布线的公司来做。这时就要特别留意,数据和语音的标签一定要在放线的时分做好,不给后续工作带来费事。
    6. In the process of decoration of many purification projects, due to the small scope, the weak current transformation (including network and telephone lines) often does not invite special integrated wiring companies to do. At this time, we should pay special attention to the data and voice labeling must be done in the wiring time, do not bring trouble to the follow-up work.
    7.如今很多的楼宇配有中央空调和新风系统,但室内出风口不一定刚好满足请求。需求装修公司拜托专业人士延长或改造出风口,并需求吊顶工程配合。
    7. Nowadays, many buildings are equipped with central air conditioning and fresh air system, but the indoor air outlet does not necessarily meet the requirements. Demand decoration company relies on professionals to extend or renovate the air outlet, and needs ceiling engineering cooperation.
    8.办公室墙面假如质量不好,刮腻子后一定要等到干透再施工。
    8. If the quality of office wall is not good, it must wait until the putty is completely dried before construction.
    9.办公室吊顶不论选用石棉板或矿棉板,都要用螺丝拉杆悬挂,这样才干经久耐用,用铁丝悬挂是绝对不允许的。
    9. Whether the office ceiling is made of asbestos or mineral wool, it must be suspended with screw and pull rod, so as to be durable. It is absolutely not allowed to suspend with wire.
    10.净化工程干净厂房装置对讲电话,不但能够便当工作人员的互相交流,还能够减少工作人员在干净区内互相走动,减少灰尘,同时还应设置火灾报警系统,避免火灾不易被发现而形成的严重损失。
    10. The intercom telephone of the clean workshop in the purification project can not only facilitate the communication between the staff, but also reduce the movement of the staff in the clean area and dust. At the same time, the fire alarm system should be set up to avoid the serious losses caused by the fire which is not easy to be found.